+86-15801907491
Home / News / Industry news / How to precisely control the release of fire extinguishing agent to optimize the fire extinguishing effect?

How to precisely control the release of fire extinguishing agent to optimize the fire extinguishing effect?

The control mechanism of the tinplate cup fire extinguisher valve is based on a precise flow control device, the core of which lies in the cooperation between the valve core and the valve seat, as well as possible auxiliary components such as springs and transmission mechanisms. The material, shape and surface treatment of the valve core must be strictly screened and designed to ensure its stability and durability during long-term storage and emergency use. The valve seat is required to have high wear resistance and sealing properties to maintain a tight fit under high pressure and high temperature conditions to prevent leakage of fire extinguishing agent.

As an important component in the valve, the elastic modulus, preload and other parameters of the spring must be accurately calculated to ensure that the valve can respond quickly to operating instructions during opening and closing, while providing stable flow regulation capabilities. In addition, for valves equipped with electronic control systems, the accuracy and reliability of components such as sensors and controllers are also crucial. They can monitor the pressure, temperature and other parameters of the fire extinguishing agent in real time, and automatically adjust the valve opening according to the preset algorithm to achieve more intelligent flow control.

During the use of tinplate cup fire extinguishers, the precise control ability of the valve is directly related to whether the fire extinguishing agent can be sprayed to the fire source at an appropriate pressure and flow rate. On the one hand, if the flow rate of the fire extinguishing agent is too large, it will not only cause the fire extinguishing agent to be quickly exhausted, but also may cause secondary damage to the surrounding environment and personnel due to excessive impact force. On the other hand, if the flow rate is too small, the fire extinguishing agent may not be able to quickly cover the fire source, resulting in poor fire extinguishing effect, or even delaying the fire extinguishing opportunity.

The design of the tinplate cup fire extinguisher valve must fully consider factors such as the type of fire source, the type of fire extinguishing agent, and the use environment, and determine the optimal flow control parameters through precise calculation and experimental verification. For example, for different types of fires (such as Class A solid fires, Class B liquid fires, Class C gas fires, Class D metal fires, etc.), different types of fire extinguishing agents need to be selected, and the flow control strategy of the valve needs to be adjusted accordingly. The valve must also have the ability to maintain a good working condition in extreme environments (such as high temperature, high pressure, low temperature, low humidity, etc.) to ensure that it can respond quickly and effectively extinguish fires in emergency situations.

In the actual application of tinplate cup fire extinguishers, the precise control ability of the valve not only helps to optimize the fire extinguishing effect, but also effectively avoids the waste of fire extinguishing agent and secondary damage. By precisely controlling the outflow speed and amount of the fire extinguishing agent, the valve can ensure that the fire extinguishing agent covers the fire source in the most optimized way, without wasting due to excessive use, and without affecting the fire extinguishing effect due to insufficient flow.

The design of the valve also needs to consider the environmental treatment after the fire extinguishing. For example, for some types of fire extinguishing agents (such as dry powder fire extinguishing agents), excessive use may cause environmental pollution or personnel health risks. Therefore, the valve needs to have the ability to quickly stop the release of fire extinguishing agent after the fire is over to reduce the negative impact on the environment. The valve should also be easy to clean and maintain so that its performance stability and reliability can be maintained during long-term use.